X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 293 0.3M MgSO4, 16% PEG 3350, pH 7.0, VAPOR DIFFUSION, SITTING DROP, temperature 293K
Unit Cell:
a: 106.232 Å b: 106.232 Å c: 517.557 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 43 21 2
Crystal Properties:
Matthew's Coefficient: 3.52 Solvent Content: 65.05
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.953 37.169 46866 2353 73.54 0.2348 0.2876 58.6857
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.95 50 78.5 ? ? ? ? 50131 50131 2.0 2.0 44.650
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.95 3.06 78.5 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRF BEAMLINE BL17U 0.9794 SSRF BL17U
Software
Software Name Purpose Version
HKL-2000 data collection .
PHASES phasing .
PHENIX refinement (phenix.refine: 1.6.4_486)
HKL-2000 data reduction .
HKL-2000 data scaling .