X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 298 20% PEG6000, 0.1M MES, 5 M Zn acetate,0.1% - mercaptoethanol, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K
Unit Cell:
a: 93.780 Å b: 105.290 Å c: 114.760 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.04 Solvent Content: 39.63
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 3.20 42.83 36165 2139 99.9 0.216 0.316 39.50
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
3.200 43.400 99.9 0.26000 ? 3.3000 6.700 ? 36165 ? 2.000 45.40
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 3.20 3.31 99.9 ? ? 1.100 5.70 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON BESSY BEAMLINE 14.2 ? BESSY 14.2
Software
Software Name Purpose Version
HKL-2000 data collection .
PHENIX model building (phenix.autoMR:1.6_289)
PHENIX refinement (phenix.refine: 1.6_289)
iMOSFLM data reduction .
SCALA data scaling .
PHENIX phasing .