X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.0 293 11.7% PEG20000, 0.1 M sodium acetate, pH 5.0, 100 mM potassium/sodium tartrate, 20 mM lithium sulfate, 10 mM CHES, pH 9.5, VAPOR DIFFUSION, SITTING DROP, temperature 293K
Unit Cell:
a: 63.620 Å b: 155.680 Å c: 74.760 Å α: 90.00° β: 110.40° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 3.61 Solvent Content: 65.96
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.648 39.170 37086 1860 93.71 0.2102 0.2576 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.648 39.17 96 ? ? 15.7 5.0 39686 38111 -99 -99 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.65 2.72 68.1 ? ? 2.5 3.6 1959
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRL BEAMLINE BL12-2 ? SSRL BL12-2
Software
Software Name Purpose Version
Web-Ice data collection .
PHASER phasing .
PHENIX refinement (phenix.refine: 1.7_650)
XDS data reduction .
XDS data scaling .