3R8Y

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7 298 20% PEG 3350, 200mM Calcium Chloride, pH 7, VAPOR DIFFUSION, HANGING DROP, temperature 298K
Unit Cell:
a: 52.421 Å b: 52.219 Å c: 134.550 Å α: 97.41° β: 93.19° γ: 115.71°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.11 Solvent Content: 41.83
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.700 29.406 138207 6928 99.31 0.1880 0.2209 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.70 50 99.3 0.099 ? 13.6 5.7 143723 142717 1.5 2.3 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.70 1.76 98.8 ? ? 2.3 4.5 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 110 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 21-ID-G 0.97857 APS 21-ID-G
Software
Software Name Purpose Version
PHENIX refinement 1.7_650
PDB_EXTRACT data extraction 3.10
BLU-MAX data collection .
HKL-2000 data reduction .
HKL-2000 data scaling .
MrBUMP/MolRep phasing .