X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 298 190 mM ammonium iodide, 23% PEG 3350, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K
Unit Cell:
a: 29.964 Å b: 162.656 Å c: 34.387 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 2.15 Solvent Content: 42.80
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.0100 81.3800 5163 232 86.5000 0.2348 0.2978 37.226
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.000 81.38 97.000 0.099 ? 12.000 10.2 5774 5774 ? -3.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.000 2.070 84.100 ? ? ? 7.200 481
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 24-ID-C 1.4938 APS 24-ID-C
Software
Software Name Purpose Version
REFMAC refinement .
PDB_EXTRACT data extraction 3.10
ADSC data collection Quantum
DENZO data reduction .
SCALEPACK data scaling .
PHASER phasing .