X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.7 277 pH 6.7, vapor diffusion, temperature 277K
Unit Cell:
a: 59.600 Å b: 74.600 Å c: 81.900 Å α: 90.00° β: 98.30° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.52 Solvent Content: 51.21
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.40 40.52 26952 1034 96.5 0.201 0.244 47.07
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.400 50.000 97.0 0.02800 ? 43.0000 3.900 ? 26953 ? 0.000 51.10
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.40 2.49 93.8 ? ? 14.600 3.90 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU FR-E ? ? ?
Software
Software Name Purpose Version
BUSTER-TNT refinement BUSTER 2.9.7
PDB_EXTRACT data extraction 3.10
HKL-2000 data reduction (DENZO)
HKL-2000 data scaling (SCALEPACK)
AMoRE phasing .
BUSTER refinement 2.9.7
Feedback Form
Name
Email
Institute
Feedback