X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 277 pH 7.0, vapor diffusion, temperature 277K
Unit Cell:
a: 75.400 Å b: 75.400 Å c: 153.800 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 32 2 1
Crystal Properties:
Matthew's Coefficient: 3.53 Solvent Content: 65.20
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.2700 40.3200 23972 701 99.2000 0.2400 0.2890 48.1051
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.260 50.000 99.700 0.098 ? 16.400 9.500 ? 24039 ? 0.000 36.300
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.260 2.340 99.700 ? ? 4.7 9.000 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU FR-E SUPERBRIGHT 1.54 ? ?
Software
Software Name Purpose Version
CNS refinement .
PDB_EXTRACT data extraction 3.10
HKL-2000 data reduction (DENZO)
HKL-2000 data scaling (SCALEPACK)
AMoRE phasing .
CNX refinement 2005