X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.2 293 0.8M phosphate, pH 8.2, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 45.098 Å b: 106.606 Å c: 47.541 Å α: 90.00° β: 101.92° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.00 Solvent Content: 38.53
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.50 19.20 66447 3441 99.78 0.14537 0.17646 10.463
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.20 50 99.3 0.081 ? 16.9 5 ? 135290 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.20 1.24 98.4 ? ? 3.5 5 13388
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID23-1 1.0723 ESRF ID23-1
Software
Software Name Purpose Version
DNA data collection .
PHASER phasing .
REFMAC refinement 5.2.0019
DENZO data reduction .
SCALEPACK data scaling .