X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.6 293 0.1M Tris 16% PEG 3350 , pH 8.6, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 45.431 Å b: 50.873 Å c: 66.894 Å α: 98.16° β: 101.98° γ: 93.54°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.31 Solvent Content: 46.68
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.79 26.21 51102 2606 93.91 0.1854 0.2163 38.92
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.79 44.2 94.0 0.035 ? 20.0 3.52 54332 51111 -3.0 -3.0 30.47
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.79 1.90 88.8 ? ? 4.2 3.4 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SLS BEAMLINE X06SA 1.000 SLS X06SA
Software
Software Name Purpose Version
MOLREP phasing .
REFMAC refinement 5.5.0109
XDS data reduction .
BUSTER refinement 2.11.1
Feedback Form
Name
Email
Institute
Feedback