X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6 298 0.1M MES pH6.0, 0.2M Zn(OAc)2, 10%(w/v)PEG-8000, VAPOR DIFFUSION, HANGING DROP, temperature 298K
Unit Cell:
a: 4.834 Å b: 17.682 Å c: 40.322 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 1.55 Solvent Content: 20.39
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.5000 20.1600 609 61 87.5000 0.1818 0.2189 9.4571
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.500 80.000 86.400 0.149 ? 8.900 4.900 621 621 ? -3.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.500 1.550 74.000 ? ? ? 2.600 54
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 24-ID-E 0.9791 APS 24-ID-E
Software
Software Name Purpose Version
DENZO data reduction .
SCALEPACK data scaling .
PHASER phasing .
REFMAC refinement .
PDB_EXTRACT data extraction 3.10
ADSC data collection Quantum