X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 277 1.1-1.6 mg/ml protein in 5mM HEPES buffer, 20mM NaCl, 1.5mM MgCl2, 0.5-1mM CaCl2, 0.1mM EGTA, 0.5mM DTT, 2mM NaN3, 0.5 ug/ml leupeptin, 0.7 ug/ml pepstatin-A and 7.5% (w/v) of polyethylene glycol 3350 (PEG 3350) or polyethylene glycol monomethyl ether 2000 (MME PEG 2K). The reservoir solution: 10 mM HEPES, 40mM NaCl, 3 mM MgCl2, 2 mM NaN3 and 15% PEG 3350 or MME, PEG 2K, pH 7.0, VAPOR DIFFUSION, temperature 277K
Unit Cell:
a: 50.737 Å b: 68.779 Å c: 79.305 Å α: 77.41° β: 85.94° γ: 73.61°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.90 Solvent Content: 57.58
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.250 48.672 45375 1904 95.17 0.1913 0.2414 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.24 50 96.2 0.074 0.074 16.9 3.6 ? 46183 3 0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.24 2.33 82.0 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON NSLS BEAMLINE X29A 1.075 NSLS X29A
Software
Software Name Purpose Version
HKL-2000 data collection .
PHASER phasing .
PHENIX refinement (phenix.refine: 2009_12_14_1757)
HKL-2000 data reduction .
HKL-2000 data scaling .