X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.2 293 100mM sodium cacodylate, 100 mM sodium acetate, 16-18% isopropanol, pH 6.2, vapor diffusion, temperature 293K
Unit Cell:
a: 59.119 Å b: 69.086 Å c: 88.623 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.23 Solvent Content: 44.79
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.2000 44.3200 111664 5582 98.1000 0.1370 0.1587 13.9864
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.200 54.486 98.300 0.049 0.049 19.800 5.400 111751 111751 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.200 1.260 91.400 ? 0.244 2.5 3.400 14955
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-4 1.07 ESRF ID14-4
Software
Software Name Purpose Version
MOSFLM data reduction .
SCALA data scaling 3.2.25
MOLREP phasing .
REFMAC refinement .
PDB_EXTRACT data extraction 3.10
ADSC data collection Quantum
Feedback Form
Name
Email
Institute
Feedback