X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.0 277.15 0.1M sodium malonate, 12% PEG 3350, 3% D-(+)-glucose monohydrate , pH 5.0, VAPOR DIFFUSION, HANGING DROP, temperature 277.15K
Unit Cell:
a: 107.625 Å b: 107.625 Å c: 171.391 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 62 2 2
Crystal Properties:
Matthew's Coefficient: 4.59 Solvent Content: 73.20
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.9 48.708 12995 651 95.23 0.2064 0.2598 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.90 50.00 100 0.103 0.135 ? 29.8 13503 13503 1.0 1.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ALS BEAMLINE 8.2.1 1.000 ALS 8.2.1
Software
Software Name Purpose Version
HKL-2000 data collection .
BALBES phasing .
PHENIX refinement (phenix.refine: 1.6.2_431)
HKL-2000 data reduction .
HKL-2000 data scaling .