X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 298 100 mM Bis-tris-propane, 20% (w/v) PEG3350, 200 mM NaBr, pH 8.5, VAPOR DIFFUSION, SITTING DROP, temperature 298K
Unit Cell:
a: 64.370 Å b: 67.899 Å c: 147.408 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.40 Solvent Content: 48.68
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.7000 32.3900 63699 3493 97.3100 0.1904 0.2330 16.5022
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.7 35 97.9 ? ? ? ? ? 63699 0 0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.7 1.79 97.9 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 200 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID29 0.97618 ESRF ID29
Software
Software Name Purpose Version
MOSFLM data reduction .
SCALA data scaling .
MOLREP phasing .
REFMAC refinement 5.2.0019
PDB_EXTRACT data extraction 3.10
ADSC data collection Quantum