X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 277 27% PEG 3000, 0.1M Tris, 0.2M Lithium Sulfate, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 277K
Unit Cell:
a: 57.157 Å b: 57.157 Å c: 177.725 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 61
Crystal Properties:
Matthew's Coefficient: 2.43 Solvent Content: 49.33
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.233 33.065 15730 1572 98.81 0.1745 0.2264 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.23 50 98 ? ? ? ? 15991 15730 0 -3 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 77 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 24-ID-E 0.97918 APS 24-ID-E
Software
Software Name Purpose Version
HKL-2000 data collection .
PHASER phasing .
PHENIX refinement (phenix.refine: 1.5_2)
HKL-2000 data reduction .
HKL-2000 data scaling .
Feedback Form
Name
Email
Institute
Feedback