X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7 293 1.2M phosphate, pH 7, VAPOR DIFFUSION, SITTING DROP, temperature 293K
Unit Cell:
a: 187.469 Å b: 187.469 Å c: 60.180 Å α: 90.000° β: 90.000° γ: 120.000°
Symmetry:
Space Group: H 3 2
Crystal Properties:
Matthew's Coefficient: 2.85 Solvent Content: 56.86
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.5000 26.0000 63024 3193 98.0300 0.2403 0.2631 20.6126
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.500 93.735 98.800 ? 0.019 71.900 3.800 63473 63473 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.500 1.580 95.700 ? 0.204 2.9 3.800 8931
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 ? K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-1 0.97950 ESRF ID14-1
Software
Software Name Purpose Version
SCALA data scaling 3.3.9
PHASER phasing 2.1.4
CNS refinement 1.1
PDB_EXTRACT data extraction 3.10
MOSFLM data reduction .