X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 295 1.4M sodium/potassium phosphate, 0.1M Hepes, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 295K
Unit Cell:
a: 145.670 Å b: 145.670 Å c: 136.440 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 32 2 1
Crystal Properties:
Matthew's Coefficient: 3.04 Solvent Content: 59.56
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.85 47.68 134596 7117 99.70 0.18148 0.20988 32.500
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.85 126 97 ? ? ? ? 276446 268021 ? 0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.85 1.9 90.7 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-2 0.933 ESRF ID14-2
Software
Software Name Purpose Version
DNA data collection .
MOLREP phasing .
REFMAC refinement 5.5.0102
XDS data reduction .
XSCALE data scaling .