X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 290 20% PEG 6K, 100mM Hepes, pH 7.0, VAPOR DIFFUSION, HANGING DROP, temperature 290K
Unit Cell:
a: 38.472 Å b: 61.345 Å c: 122.696 Å α: 90.000° β: 95.870° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.31 Solvent Content: 46.85
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.940 54.81 40076 2001 94.760 0.183 0.277 32.698
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.940 122.169 95.000 0.062 0.062 15.400 3.600 40132 40132 0.047 0.047 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.94 2.04 84.90 ? 0.281 2.0 3.40 5221
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-4 1.4 ESRF ID14-4
Software
Software Name Purpose Version
MOSFLM data reduction .
SCALA data scaling 3.2.17
REFMAC refinement .
PDB_EXTRACT data extraction 3.100
ADSC data collection Quantum