X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 298 0.2 M potassium citrate, 20% PEG 3350, pH 7.5, VAPOR DIFFUSION, temperature 298K
Unit Cell:
a: 295.151 Å b: 46.446 Å c: 114.952 Å α: 90.00° β: 91.42° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.23 Solvent Content: 44.76
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.552 18.934 51439 2619 99.81 0.2232 0.2630 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.55 50 ? 0.075 ? 20.5 3.7 ? 51460 ? 2 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.55 2.59 ? ? ? 2.07 3.7 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU FR-E SUPERBRIGHT 1.5418 ? ?
Software
Software Name Purpose Version
HKL-2000 data collection .
MOLREP phasing .
PHENIX refinement (phenix.refine: 1.5_2)
HKL-2000 data reduction .
HKL-2000 data scaling .