X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 295 Protein solution: 7.5 mg/mL, 0.25M Sodium Chloride, 0.01M Tris-HCL (pH 8.3); Screen solution: Classics II G1, 0.2M Sodium chloride, 0.1M TRIS (pH 8.5), 25% PEG 3350., VAPOR DIFFUSION, SITTING DROP, temperature 295K
Unit Cell:
a: 82.553 Å b: 97.903 Å c: 110.724 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.14 Solvent Content: 42.57
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.90 29.47 67705 3607 99.98 0.18802 0.23477 24.671
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.90 30.0 100.0 0.067 ? 23.7 6.4 71519 71519 ? -3.0 26.4
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.90 1.93 100.0 ? ? 4.4 6.5 3530
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 21-ID-G 0.97856 APS 21-ID-G
Software
Software Name Purpose Version
Blu-Ice data collection Max
PHASER phasing .
REFMAC refinement 5.5.0102
HKL-2000 data reduction .
HKL-2000 data scaling .
Feedback Form
Name
Email
Institute
Feedback