X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.00 293 20% PEG 3350, 0.1M potassium phosphate(pH 6.00), VAPOR DIFFUSION, SITTING DROP, temperature 293K
Unit Cell:
a: 89.784 Å b: 51.316 Å c: 95.407 Å α: 90.00° β: 112.76° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.28 Solvent Content: 46.04
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.80 43.99 33871 1798 96.02 0.18720 0.23349 23.180
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.80 50.0 96.4 0.087 0.087 20.0 5.9 37031 37031 0.0 -3.0 19.97
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.80 1.86 78.8 ? 0.363 3.5 4.8 2886
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE BM14 0.97372 ESRF BM14
Software
Software Name Purpose Version
MARMOSAIC data collection 225 MM CCD
PHASER phasing .
REFMAC refinement 5.5.0070
HKL-2000 data reduction .
HKL-2000 data scaling .
Feedback Form
Name
Email
Institute
Feedback