X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6 293 1.14M (NH4)2SO4, 0.1M MES, pH 6, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 51.602 Å b: 64.677 Å c: 69.563 Å α: 90.00° β: 96.60° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.43 Solvent Content: 49.40
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION SAD THROUGHOUT 2.70 47.22 23891 1384 97.3 0.244 0.284 59.7
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.7 50 99.7 0.067 0.059 25.3 3.8 27508 27508 0 0 50.8
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.7 2.74 99.7 ? 0.322 24.0 3.7 1387
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON NSLS BEAMLINE X4A 0.979 NSLS X4A
Software
Software Name Purpose Version
ADSC data collection Quantum
SOLVE phasing .
CNS refinement 1.2
HKL-2000 data reduction .
HKL-2000 data scaling .