X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 293 100mM Tris-HCl (pH 8.5), 25% (w/v) PEG 3350, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 102.480 Å b: 50.547 Å c: 71.323 Å α: 90.00° β: 125.01° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.27 Solvent Content: 45.83
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.80 50.00 26181 1387 98.99 0.18933 0.23325 19.055
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.8 58.42 99.1 ? ? ? ? 26832 26832 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.8 1.83 99.2 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PAL/PLS BEAMLINE 4A 1.0000 PAL/PLS 4A
Software
Software Name Purpose Version
HKL-2000 data collection .
MOLREP phasing .
REFMAC refinement 5.5.0072
HKL-2000 data reduction .
HKL-2000 data scaling .