ELECTRON MICROSCOPY


Sample

CorA from Thermotoga maritima in the presence of magnesium

Specimen Preperation
Sample Aggregation State PARTICLE
Vitrification Instrument LEICA EM GP
Cryogen Name ETHANE
Sample Vitrification Details Grids were blotted at 4 degrees Celsius for 7 seconds after a 10-second pre-blotting period, then plunge-frozen in liquid ethane.
3D Reconstruction
Reconstruction Method SINGLE PARTICLE
Number of Particles 46206
Reported Resolution (Å) 3.8
Resolution Method FSC 0.143 CUT-OFF
Other Details Final map was calculated from one dataset. (Single particle details: The particles were selected using an automatic selection program. 3D classification, 3D refinement, and postprocessing were done using RELION 1.3.) (Single particle--Applied symmetry: C5)
Refinement Type
Symmetry Type POINT
Map-Model Fitting and Refinement
ID 1
Refinement Space REAL
Refinement Protocol ?
Refinement Target ?
Overall B Value ?
Fitting Procedure ?
Details ?
Data Acquisition
Detector Type GATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å2) 40
Imaging Experiment
Date of Experiment 2014-08-21
Temprature (Kelvin)
Microscope Model FEI TITAN KRIOS
Minimum Defocus (nm) 860
Maximum Defocus (nm) 2500
Minimum Tilt Angle (degrees) ?
Maximum Tilt Angle (degrees) ?
Nominal CS 2.7
Imaging Mode BRIGHT FIELD
Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification 105000
Calibrated Magnification 105000
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 300
Imaging Details Parallel beam illumination
Imaging Experiment
Task Software Package Version
MODEL FITTING Coot ?
MODEL FITTING PHENIX ?
MODEL FITTING UCSF Chimera ?
RECONSTRUCTION RELION ?
Image Processing
CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details
. CTF parameters obtained from whole micrograph