ELECTRON MICROSCOPY


Sample

Coxsackievirus B3 complexed with CAR

Specimen Preperation
Sample Aggregation State PARTICLE
Vitrification Instrument FEI VITROBOT MARK III
Cryogen Name OTHER
Sample Vitrification Details Plunged into ethane-propane (FEI VITROBOT MARK III)
3D Reconstruction
Reconstruction Method SINGLE PARTICLE
Number of Particles 9302
Reported Resolution (Å) 9.0
Resolution Method FSC 0.5 CUT-OFF
Other Details (Single particle details: Particles were selected using EMAN) (Single particle--Applied symmetry: I)
Refinement Type
Symmetry Type POINT
Map-Model Fitting and Refinement
ID 1
Refinement Space REAL
Refinement Protocol RIGID BODY FIT
Refinement Target correlation coefficient
Overall B Value ?
Fitting Procedure ?
Details REFINEMENT PROTOCOL--rigid body
Data Acquisition
Detector Type KODAK SO-163 FILM
Electron Dose (electrons/Å2) 15
Imaging Experiment
Date of Experiment 2012-08-01
Temprature (Kelvin)
Microscope Model FEI TECNAI F20
Minimum Defocus (nm) 1980
Maximum Defocus (nm) 3660
Minimum Tilt Angle (degrees) 0.0
Maximum Tilt Angle (degrees) 0.0
Nominal CS 2
Imaging Mode BRIGHT FIELD
Specimen Holder Model GATAN LIQUID NITROGEN
Nominal Magnification 50000
Calibrated Magnification 50000
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 200
Imaging Details ?
Imaging Experiment
Task Software Package Version
MODEL FITTING Situs ?
RECONSTRUCTION Auto3DEM ?
RECONSTRUCTION EMAN ?
Image Processing
CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details
. AUTO3DEM