ELECTRON MICROSCOPY
Sample
TubZ-Bt
Specimen Preperation
Sample Aggregation State
FILAMENT
Vitrification Instrument
FEI VITROBOT MARK III
Cryogen Name
ETHANE
Sample Vitrification Details
Add GTP to grow filaments for 6 minutes before application to grid. Blot 4.5 seconds before plunging into liquid ethane (FEI VITROBOT MARK III).
3D Reconstruction
Reconstruction Method
HELICAL
Number of Particles
?
Reported Resolution (Å)
6.8
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Final map has been low-pass filtered to 7 Angstrom and high-pass filtered to 30 Angstrom. A B-factor of -309 Angstrom was applied using the program bfactor. A cylindrical mask of radius ~80 Angstrom has been applied.
Refinement Type
Symmetry Type
HELICAL
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
?
Refinement Target
?
Overall B Value
?
Fitting Procedure
?
Details
DETAILS--Initial local fitting was done using Chimera and then Molecular Dynamics Flexible Fitting (MDFF) was used for flexible fitting.
Data Acquisition
Detector Type
TVIPS TEMCAM-F816 (8k x 8k)
Electron Dose (electrons/Å
2
)
20
Imaging Experiment
Date of Experiment
2011-04-22
Temprature (Kelvin)
Microscope Model
FEI TECNAI F20
Minimum Defocus (nm)
800
Maximum Defocus (nm)
3500
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
2.2
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
OTHER
Nominal Magnification
62000
Calibrated Magnification
?
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
200
Imaging Details
?
Imaging Experiment
Task
Software Package
Version
MODEL FITTING
MDFF
?
RECONSTRUCTION
SPIDER
?
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
.
Whole Micrograph