Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Virus Classification
Indian Data
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
3J31
pdb_00003j31
10.2210/pdb3j31/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
Mature Sulfolobus Turreted Icosahedral Virus
Specimen Preperation
Sample Aggregation State
PARTICLE
Vitrification Instrument
HOMEMADE PLUNGER
Cryogen Name
ETHANE
Sample Vitrification Details
Vitrification carried out at room temperature using liquid ethane and a homemade plunger
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
8903
Reported Resolution (Å)
4.5
Resolution Method
FSC 0.143 CUT-OFF
Other Details
The final reconstruction was sharpened with a negative temperature factor of 400A2 (Single particle--Applied symmetry: I) Resolution method was FSC at 0.143 cut-off. The reported resolution is for the entire reconstruction. The resolution of the coat subunit region (B345) is estimated to 3.9 A using the same criterion.
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
RECIPROCAL
Refinement Protocol
FLEXIBLE FIT
Refinement Target
?
Overall B Value
?
Fitting Procedure
?
Details
REFINEMENT PROTOCOL--positional (xyz) minimization and isotropic B factor refinement DETAILS--Real space refinement was also carried out using Coot.
Data Acquisition
Detector Type
FEI FALCON I (4k x 4k)
Electron Dose (electrons/Å
2
)
18
Imaging Experiment
Date of Experiment
2011-03-30
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
800
Maximum Defocus (nm)
2500
Minimum Tilt Angle (degrees)
0
Maximum Tilt Angle (degrees)
0
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
?
Calibrated Magnification
102189
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
Nanoprobe mode was used.
Imaging Experiment
Task
Software Package
Version
MODEL FITTING
CNS
?
RECONSTRUCTION
FREALIGN
?
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
.
Each particle