X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.3 298 7-8% (W/V) polyethylene glycol 20000, 50mM MES, pH 6.3, VAPOR DIFFUSION, HANGING DROP, temperature 298K
Unit Cell:
a: 74.762 Å b: 104.732 Å c: 115.035 Å α: 90.00° β: 108.24° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.23 Solvent Content: 44.78
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.90 42.15 122222 12186 92.3 0.176 0.211 15.2
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.9 50 96.7 0.083 ? 8.8 3.4 128987 128987 0.0 0.0 10.1
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.90 1.97 96.8 ? ? 3.4 3.2 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PHOTON FACTORY BEAMLINE BL-6A 0.978 Photon Factory BL-6A
Software
Software Name Purpose Version
ADSC data collection Quantum
MOLREP phasing .
CNS refinement 1.1
HKL-2000 data reduction .
HKL-2000 data scaling .