X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 9.0 290 JCSG+ Screen B3: 20% PEG 6000, 100mM Bicine pH 9.0. Protein at 22 mg/mL, VAPOR DIFFUSION, SITTING DROP, temperature 290K
Unit Cell:
a: 94.320 Å b: 94.320 Å c: 236.930 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 31 2 1
Crystal Properties:
Matthew's Coefficient: 2.18 Solvent Content: 43.67
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.10 47.95 72027 3633 99.8 0.196 0.245 27.67
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.10 50.0 99.8 0.059 ? 27.31 8.9 72100 72100 0 -3.0 39.63
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.10 2.15 99.9 ? ? 3.900 8.4 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100.0 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRL BEAMLINE BL12-2 0.97946 SSRL BL12-2
Software
Software Name Purpose Version
Blu-Ice data collection .
PHASER phasing .
REFMAC refinement 5.5.0088
XDS data reduction .
XSCALE data scaling .