X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 277 0.1 M Tris-HCl (pH 8.5), 30% w/v polyethylene glycol 4000, and 0.2 M sodium acetate, VAPOR DIFFUSION, HANGING DROP, temperature 277K
Unit Cell:
a: 43.907 Å b: 131.453 Å c: 60.200 Å α: 90.000° β: 92.870° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.61 Solvent Content: 52.85
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.900 50.000 48583 2443 90.700 ? 0.258 19.278
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.90 50 ? 0.081 ? 16.1 4.0 53537 48583 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.90 1.97 81.8 ? ? 3.8 3.7 4324
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 19-BM 0.979 APS 19-BM
Software
Software Name Purpose Version
CNS refinement .
PDB_EXTRACT data extraction 3.005
HKL-2000 data collection .
HKL-2000 data reduction .
HKL-2000 data scaling .
CNS phasing .
Feedback Form