X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.0 293 63 mM Magnesium acetate, 12.6% PEG 8000, 90 mM Sodium cacodylate, 10 mM Sodium acetate pH 4.6, 60 mM Sodium fluoride, VAPOR DIFFUSION, SITTING DROP, temperature 293K
Unit Cell:
a: 91.000 Å b: 91.000 Å c: 211.600 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 65 2 2
Crystal Properties:
Matthew's Coefficient: 2.87 Solvent Content: 57.18
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 3.10 32.190 9362 492 93.39 0.2305 0.2673 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
3.05 50.0 99.7 ? 0.134 ? ? ? 10527 ? 2.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 3.05 3.16 100 ? 0.697 2.1 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 24-ID-E 0.97921 APS 24-ID-E
Software
Software Name Purpose Version
PHENIX refinement 1.4_162
PDB_EXTRACT data extraction 3.005
ADSC data collection Quantum
DENZO data reduction .
SCALEPACK data scaling .
CNS phasing .
CNS refinement .