X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.0 298 100mM MES, pH 6.0, 15% PEG 4000, VAPOR DIFFUSION, HANGING DROP, temperature 298K
Unit Cell:
a: 41.635 Å b: 52.725 Å c: 65.260 Å α: 106.34° β: 92.05° γ: 95.11°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.25 Solvent Content: 45.31
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.75 20.00 48456 2590 100.00 0.19821 0.23605 27.461
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.75 30 96.8 ? ? ? ? 51062 51062 0.0 0.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.75 1.81 89.7 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON CHESS BEAMLINE A1 0.9771 CHESS A1
Software
Software Name Purpose Version
ADSC data collection Quantum
MOLREP phasing .
REFMAC refinement 5.3.0021
HKL-2000 data reduction .
HKL-2000 data scaling .
Feedback Form
Name
Email
Institute
Feedback