X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 293 9-20% PEG 6000, 0.1M tri-Na Citrate, 0-0.1M NaCl, pH 6.5, vapor diffusion, hanging drop, temperature 293K
Unit Cell:
a: 56.610 Å b: 79.879 Å c: 57.893 Å α: 90.000° β: 116.330° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.63 Solvent Content: 53.30
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.810 14.500 41305 4184 99.660 0.195 0.227 23.282
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.800 50 93.1 0.034 0.034 28.45 3.7 ? 46082 0 0 25.566
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.80 1.86 76.3 ? 0.258 5.7 3.6 3043
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-2 0.933 ESRF ID14-2
Software
Software Name Purpose Version
XSCALE data scaling .
AMoRE phasing .
REFMAC refinement 5.2.0019
PDB_EXTRACT data extraction 3.006
ADSC data collection Quantum
XDS data reduction .