X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.75 293 0.1 M MES, 25% PEG 1000, pH 6.75, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 84.223 Å b: 84.223 Å c: 138.535 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 43 21 2
Crystal Properties:
Matthew's Coefficient: 2.56 Solvent Content: 52.04
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.50 19.79 16678 889 98.01 0.21747 0.28375 15.430
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.5 20 98 0.125 ? 16.7 7.0 17556 17486 1.0 1.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.5 2.56 98 ? ? 3.6 6.8 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON MAX II BEAMLINE I711 0.97 MAX II I711
Software
Software Name Purpose Version
BLi711 data collection .
MOLREP phasing .
REFMAC refinement 5.5.0066
MOSFLM data reduction .
SCALA data scaling .