X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.8 291 Drops: 20mg/mL protein in 50mM HEPES, pH 7.7, 400mM NaCl, 30% glycerol, 1mM EDTA, 10mM N,N-dimethylundecylamin-N-oxide (C11DAO) precipitant solution: 0.1M acetate pH 4.6-5.0, 40mM C11DAO, 20.8mM N,N-dimethyldecylamine-N-oxide (DDAO), 2mM dihydroorotate (DHO), 1.8-2.4M ammonium sulfate, 1mM inhibitors reservoir: 0.1M acetate pH 4.8, 2.4-2.6M ammonium sulfate, 30% glycerol , VAPOR DIFFUSION, HANGING DROP, temperature 291K
Unit Cell:
a: 90.752 Å b: 90.752 Å c: 122.799 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 32 2 1
Crystal Properties:
Matthew's Coefficient: 3.66 Solvent Content: 66.42
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.00 78.59 38077 2005 99.92 0.17128 0.20281 16.538
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.0 78.59 99.92 ? ? ? ? 40112 40082 2.00 2.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.000 2.052 99.69 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE BM14 0.98 ESRF BM14
Software
Software Name Purpose Version
DNA data collection .
PHASER phasing .
REFMAC refinement 5.5.0066
MOSFLM data reduction .
SCALA data scaling .
Feedback Form
Name
Email
Institute
Feedback