X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 9.8 293 30% PEG3K, 0.2M CaCl2, 0.05M CAPSO, pH9.8, VAPOR DIFFUSION, SITTING DROP, temperature 293K
Unit Cell:
a: 48.214 Å b: 102.862 Å c: 171.690 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.16 Solvent Content: 43.05
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.40 40.00 32409 1726 99.50 0.22422 0.28259 30.488
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.4 40 99.6 0.077 0.077 11.9 3.5 ? 34193 ? ? 41.064
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.4 2.53 99.9 ? 0.351 2.7 3.5 4926
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 110 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID23-1 1 ESRF ID23-1
Software
Software Name Purpose Version
ADSC data collection Quantum
MOLREP phasing .
REFMAC refinement 5.5.0053
MOSFLM data reduction .
SCALA data scaling .
Feedback Form
Name
Email
Institute
Feedback