X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 295 16% PEG 8000, 100 mM Tris, 10 mM DTT, pH 8.0, vapor diffusion, hanging drop, temperature 295K
Unit Cell:
a: 94.439 Å b: 50.082 Å c: 70.174 Å α: 90.000° β: 105.000° γ: 90.000°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.13 Solvent Content: 42.32
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.000 39.140 17373 845 80.300 0.226 0.251 35.781
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.000 50.000 84.000 0.107 0.107 9.943 2.900 18180 17373 0 0 4.8
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.00 2.07 72.60 ? 0.256 3.3 2.70 1560
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 24-ID-C 0.9795 APS 24-ID-C
Software
Software Name Purpose Version
DENZO data reduction .
SCALEPACK data scaling .
CNS refinement 1.2
PDB_EXTRACT data extraction 3.006
ADSC data collection Quantum
HKL-2000 data reduction .
HKL-2000 data scaling .
CNS phasing .