3EOB

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.3 277 0.1M sodium cacodylate, 0.2M zinc acetate, 11% w/v PEG 8000, pH 7.3, VAPOR DIFFUSION, HANGING DROP, temperature 277K
Unit Cell:
a: 111.096 Å b: 111.096 Å c: 470.726 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 61 2 2
Crystal Properties:
Matthew's Coefficient: 3.09 Solvent Content: 60.20
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 3.60 50.00 20553 1026 97.7 0.269 0.333 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
3.60 50.00 97.8 0.203 0.203 7.5 5.3 21109 20645 1.0 1.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 3.60 3.73 98.9 ? 0.622 2.0 4.4 2014
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PHOTON FACTORY BEAMLINE BL-17A 1.0000 Photon Factory BL-17A
Software
Software Name Purpose Version
HKL-2000 data collection .
CNS refinement .
HKL-2000 data reduction .
HKL-2000 data scaling .
CNS phasing .