X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 293 PEG 4000, ammonium acetate, pH 7.5, VAPOR DIFFUSION, temperature 293K
Unit Cell:
a: 64.028 Å b: 64.028 Å c: 111.882 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 43 21 2
Crystal Properties:
Matthew's Coefficient: 2.02 Solvent Content: 39.00
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.90 28.63 17579 955 97.42 0.192 0.225 25.182
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.900 55.571 98.000 0.062 0.062 9.4 8.800 19039 18558 ? ? 25.4
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.90 2.00 97.20 ? 0.455 4.3 9.20 2630
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE BM30A 0.9797 ESRF BM30A
Software
Software Name Purpose Version
MOSFLM data reduction .
SCALA data scaling 3.2.19
REFMAC refinement .
PDB_EXTRACT data extraction 3.006
ADSC data collection Quantum
REFMAC phasing 5