X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7 298 40 mM sodium cacodylate, 80 mM SrCl, 15% MPD, 2 mM spermine-HCl, pH 7, vapor diffusion, hanging drop, temperature 298K
Unit Cell:
a: 96.776 Å b: 96.776 Å c: 86.765 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: I 41 2 2
Crystal Properties:
Matthew's Coefficient: 2.92 Solvent Content: 57.85
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION ? THROUGHOUT 2.70 19.79 5519 538 93.6 0.227 0.255 57.1
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.7 20 93.7 0.076 0.076 13.3 3.9 ? 5520 ? 9.3 71.1
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.7 2.8 74 ? 0.284 1.7 2.8 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 24-ID-E 0.9792 APS 24-ID-E
Software
Software Name Purpose Version
CNS refinement 1.2
PDB_EXTRACT data extraction 3.006
HKL-2000 data collection .
HKL-2000 data reduction .
HKL-2000 data scaling .
PHASER phasing .