X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 289 0.1M HEPES PH 7.5, 15-20% PEG 3350, 0.04M CALCIUM CHLORIDE, VAPOR DIFFUSION, temperature 289K
Unit Cell:
a: 57.988 Å b: 38.735 Å c: 111.172 Å α: 90.00° β: 94.47° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 1.88 Solvent Content: 34.69
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.75 30.00 11984 663 96.0 0.199 0.274 52.32
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.750 50.000 95.9 0.068 ? 8.5000 2.700 ? 12743 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.75 2.85 97.7 ? ? ? 2.60 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100.0 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON BSRF BEAMLINE 3W1A ? BSRF 3W1A
Software
Software Name Purpose Version
MOLREP phasing .
REFMAC refinement 5.2.0005
HKL-2000 data reduction .
DENZO data reduction .
SCALEPACK data scaling .