3E2Y

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 277 21% PEG 400, 150 mM CaCl2, 10% glycerol, 100 mM HEPES, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K
Unit Cell:
a: 91.567 Å b: 91.567 Å c: 232.536 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 43 21 2
Crystal Properties:
Matthew's Coefficient: 2.38 Solvent Content: 48.33
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.26 29.87 42764 2273 95.40 0.17721 0.22141 27.831
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.26 30.00 95.4 0.090 ? ? 10.3 47345 45176 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.26 2.34 ? ? ? ? 2.1 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON NSLS BEAMLINE X29A 1.0809 NSLS X29A
Software
Software Name Purpose Version
REFMAC refinement 5.2.0005
HKL-2000 data collection .
DENZO data reduction .
SCALA data scaling .
MOLREP phasing .