X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 298 16-20% PEG 6000, Tris HCl, 0.1 M, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K
Unit Cell:
a: 50.879 Å b: 65.993 Å c: 52.764 Å α: 90.000° β: 113.480° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.31 Solvent Content: 46.83
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION ? THROUGHOUT 1.750 27.27 31926 1624 99.150 0.188 0.231 24.179
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.75 50.000 99.600 0.068 ? ? 4.000 31957 31957 0 0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.75 1.82 97.00 ? ? 2.6 3.50 3098
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100.0 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 19-BM 0.97921 APS 19-BM
Software
Software Name Purpose Version
DENZO data reduction .
SCALEPACK data scaling .
REFMAC refinement .
PDB_EXTRACT data extraction 3.006
EPICS-based data collection data aquisition system