X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 298 0.1 M sodium phosphate, 0.25 M sodium citrate, 0.3 M sodium chloride, 23% polyethylene glycol 400, 0.2 M ammonium acetate, pH 8.5, sitting drop vapor diffusion, temperature 298K
Unit Cell:
a: 71.742 Å b: 71.742 Å c: 55.488 Å α: 90.000° β: 90.000° γ: 120.000°
Symmetry:
Space Group: P 32 2 1
Crystal Properties:
Matthew's Coefficient: 4.36 Solvent Content: 71.81
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.500 23.490 5934 267 99.710 0.186 0.230 42.155
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.500 25.000 99.700 0.084 ? 18.900 5.600 ? 5940 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.50 2.59 100.00 ? ? ? 5.20 584
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 143 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE ? 1.5418 ? ?
Software
Software Name Purpose Version
DENZO data reduction .
SCALEPACK data scaling .
PHASER phasing .
DM phasing .
REFMAC refinement 5.4.0066
PDB_EXTRACT data extraction 3.006
HKL-2000 data scaling .