X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.2 298 top solution: 83 mM HEPES pH 7.2, 1.2M KCl, 20% PEG6000, 1mM GDP; reservoir: 83mM HEPES pH 7.2, 0.6M KCl, 20% PEG6000, 1 mM GDP. Protein was mixed 1:1 or 1:2 with top solution, and equilibrated over the reservoir solution., VAPOR DIFFUSION, temperature 298K
Unit Cell:
a: 51.744 Å b: 108.755 Å c: 83.347 Å α: 90.00° β: 96.33° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.16 Solvent Content: 42.97
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.303 82.76 38151 2005 98.87 0.18908 0.23786 25.015
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.303 82.76 98.9 ? ? ? ? 40179 38587 ? -3 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.303 2.38 97 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ALS BEAMLINE 8.2.1 1.0 ALS 8.2.1
Software
Software Name Purpose Version
ADSC data collection Quantum
PHASER phasing .
REFMAC refinement 5.2
HKL-2000 data reduction .
HKL-2000 data scaling .