X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION
X-RAY DIFFRACTION
Unit Cell:
a: 99.182 Å b: 104.857 Å c: 109.816 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 3.01 Solvent Content: 59.14
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION SAD THROUGHOUT 2.2500 47.3100 54515 5545 99.0000 ? 0.2630 33.2045
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.250 50.000 99.600 0.069 ? 15.700 6.700 55061 55061 ? ? 26.9
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.250 2.330 97.400 ? ? 11.0 6.100 5307
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SPRING-8 BEAMLINE BL26B2 0.9789 SPring-8 BL26B2
Software
Software Name Purpose Version
DENZO data reduction .
SCALEPACK data scaling .
SOLVE phasing 2.12
RESOLVE phasing 2.12
CNS refinement 1.3
PDB_EXTRACT data extraction 3.10
HKL-2000 data collection .
HKL-2000 data reduction .
HKL-2000 data scaling .