3AH9

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 277 11.3% PEG 200, 5%(v/v) acetic acid, 0.5%(w/v) sodium azide, VAPOR DIFFUSION, HANGING DROP, temperature 277K
Unit Cell:
a: 26.416 Å b: 25.990 Å c: 80.241 Å α: 90.00° β: 90.03° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 1.86 Solvent Content: 38.92
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.08 10.00 46579 2325 93.9 ? 0.1906 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.08 10.0 98.9 0.062 ? 7.1 3.5 ? 46590 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.08 1.12 100.0 ? ? ? 3.5 4626
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 95 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PHOTON FACTORY BEAMLINE BL-6A 0.978 Photon Factory BL-6A
Software
Software Name Purpose Version
HKL-2000 data collection .
PHASER phasing .
SHELXL-97 refinement .
HKL-2000 data reduction .
HKL-2000 data scaling .