X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.50 ? 100 mM Tris/HCl, 1 mM DTT, 5% PEG 8000, 10% DMSO, pH 8.50
Unit Cell:
a: 90.730 Å b: 64.830 Å c: 70.810 Å α: 90.00° β: 96.31° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.39 Solvent Content: 48.48
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R 1.60 28.42 51779 ? 98.6 ? 0.2210 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.600 50.000 98.6 0.13310 0.07100 15.00 2.900 ? 53101 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 ? K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU ? ? ?
Software
Software Name Purpose Version
SHELX model building .
SHELXL-97 refinement .
HKL-2000 data reduction .
HKL-2000 data scaling .
CNS phasing .
Feedback Form
Name
Email
Institute
Feedback