X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.9 291 15% PEG8000, 50mM potassium phosphate, 80mM melibiose, pH4.9, VAPOR DIFFUSION, HANGING DROP, temperature 291K
Unit Cell:
a: 57.661 Å b: 74.733 Å c: 94.549 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.36 Solvent Content: 47.96
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.10 8.00 21343 1150 100.00 0.18382 0.2402 17.655
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.10 8.00 96.4 ? 0.076 22.8 ? 23358 22517 1.0 1.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.10 2.17 93.4 ? 0.213 8.1 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE MACSCIENCE 1.5418 ? ?
Software
Software Name Purpose Version
REFMAC refinement 5.2.0019
HKL-2000 data collection .
DENZO data reduction .
HKL-2000 data scaling .
MOLREP phasing .
Feedback Form
Name
Email
Institute
Feedback