X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 293 20% Pentaerythritol ethoxylate (15/4 EO/OH), 0.1M ammonium sulfate, 0.1M Bis-Tris, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 50.331 Å b: 71.687 Å c: 108.103 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.32 Solvent Content: 46.95
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.00 45.63 26941 1351 99.1 ? 0.262 35.8
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.0 50 99.3 0.063 ? 13.0 5.61 ? 26941 ? 2.0 17.7
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.0 2.07 99.0 ? ? 4.8 4.27 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SPRING-8 BEAMLINE BL32B2 1.0 SPring-8 BL32B2
Software
Software Name Purpose Version
CNX refinement 2005
CrystalClear data collection .
d*TREK data reduction .
d*TREK data scaling .
AMoRE phasing .